| Sign In | Join Free | My infospaceinc.com |
|
Brand Name : HUATEC
Model Number : HCDX-A
Certification : CE
Place of Origin : China
MOQ : 1 SET
Payment Terms : T/T,Western Union,Paypal
Supply Ability : 10 Sets/Month
Delivery Time : 7-10 working days after receipt of your payment
Packaging Details : carton packaging
Power supply : AC 220V ± 10% 50HZ 5A
Inspection speed : ≥6 m/min
gap time : ≥5 seconds
Output : AC 38V 10A
Temperature rise of probe : ≤60℃
magnetizing time : ≤3 seconds
Lifting force : AC≥ 4.5kg DC≥18Kg
Pole distance : 20-160mm (adjustable)
HCDX-A Composite Multifunctional Magnetic Particle Flaw Detector with Multi-Probe A/D/E/O Optional
Introduction:
HCDX-A composite magnetic powder flaw detector adopts silicon controlled contactless switch, with low noise, strong magnetic force, long service life and simple operation, suitable for field and laboratory use. The instrument adopts combined configuration, and users can choose probe freely according to their needs. Type A, D, E, O probe can be configured according to user requirements.
All optional probes parameters:
|
D type probe |
Lifting force: AC≥5Kg DC≥18Kg (no joints) Pole distance: 50-200mm (adjustable) Operating current: ≥8A Working voltage: AC=38V, DC=9V Weight: 2.5 Kg |
|
Atype probe |
Lifting force: AC≥ 4.5kg DC≥18Kg Pole distance: 20-160mm (adjustable) Working voltage: AC=38V, DC=9V Weight: 2.0 Kg |
|
Otype probe |
Central magnetic intensity: 180Oe Working voltage: AC=38V Inside diameter: 150 mm Weight: 2.5 Kg |
|
Etype probe |
Lifting force: ≥12Kg Distance: 110 mm Operating current: ≥7A Inspection speed: 6 m/min Working voltage: 38 v left, 2 Weight: 3.0 Kg |
Application:
Mainly used to detect surface and near surface cracks of ferromagnetic workpiece.
Boiler pressure vessel, steel structure, forgings, castings, welding parts, machined parts, etc.
The standard probes introduction for model HCDX-A:
Type A probe (horseshoe probe): suitable for all kinds of fillet weld, large workpiece inside and outside corners of local magnetization inspection, equipped with working lights.
Technical parameters:
Power supply: AC 220V ± 10% 50HZ 5A
Output: AC 38V 10A
Type A.D.E.O probes are optional and available
Inspection speed: ≥6 m/min
Temperature rise of probe: ≤60℃
Working beat: it is recommended to work for a long period of continuous operation: magnetizing time ≤3 seconds, gap time ≥5 seconds
Weight: about 6.5Kg (main unit)
Standard delivery:
Host HCDX-A 1
Type A probe 1
The power line 1
The probe line 1
Standard specimen 1
Operation manual 1
Certificate 1
Optional accessories:
Type A probe
O the probe
E probe
D probe
Dead weight
Test specimen
UV light

|
|